Skip to content
SoundBroker
LIVE FLOOR
Sold in March 2007

This listing has sold (March 2007).

The record stays here for reference: specifications, condition and photos. It can't be bought or offered on.

1 / 1 · Photo
APOGEE MA SERIES

Sold · photos kept for reference

Specifications

Power per channel
160 W

Seller's description

YEAR (?), SERIAL TBD. APOGEE'S MA SERIES AMPLIFIER PROVIDES RELIABLE, MULTICHANNEL POWER AND A HOST OF FEATURES NOT FOUND IN OTHER COMMERCIAL AMPLIFICATION PRODUCTS. THE MODULAR FORMAT ALLOWS YOU TO PURCHASE THE NUMBER OF CHANNELS YOU NEED NOW, WHILE EASILY EXPANDING AS YOUR FUTURE REQUIREMENTS GROW. SERVICE WHEN NEEDED IS SIMPLE BECAUSE CHANNEL CARDS CAN BE EASILY REMOVED AND REPLACED FROM THE FRONT PANEL, WITHOUT REMOVING THE MAINFRAME FROM THE RACK. THE MA IS AVAILABLE IN TWO BASIC MODELS: SERIES A HAS ALL THE FEATURES DESCRIBED BELOW, WHILE SERIES B IS AN ECONOMY MODEL FOR INSTALLATIONS NOT REQUIRING SIGNAL SWITCHING AND LOAD MONITORING. BOTH MODELS USE IDENTICAL AMPLIFICATION STAGES FEATURING CLASS D SWITCHING TOPOLOGY FOR REDUCED HEAT AND SPACE REQUIREMENTS, WITH INCREASED COMPONENT LIFE. LARGE INSTALLATIONS CAN BENEFIT FROM CONSIDERABLE SAVINGS IN AIR CONDITIONING REQUIREMENTS. BOTH MODELS MAY BE POWERED FROM AN OPTIONAL 48 VDC BATTERY BACKUP UNIT FOR EMERGENCY OPERATION. BATTERIES ARE OF THE SEALED GEL TYPE, WITH A TEN YEAR SERVICE LIFE. THE MA SERIES A AMPLIFIER OFFERS THESE IMPORTANT FEATURES: PRECISION, SWITCHED ATTENUATION IN 1/2 DB INCREMENTS INSURES THAT LEVELS CAN BE LOGGED AND DUPLICATED AS NEEDED. A CONTINUOUSLY VARIABLE POT CAN BE USED IN CONJUNCTION WITH THE ATTENUATION SWITCHES FOR CONTINUOUSLY VARIABLE CONTROL WHEN INITIALLY ESTABLISHING GAIN SETTINGS. A CUE SWITCH ON EACH CHANNEL PROVIDES A PADDED, LINE LEVEL FEED OF THE ACTUAL AMPLIFIER OUTPUT FOR VERIFICATION OR TROUBLESHOOTING. ANY NUMBER OF CHANNELS MAY BE CUED SIMULTANEOUSLY. BUILT-IN IMPEDANCE SENSING TRIGGERS A LOWOR HIGH FAULT INDICATOR ON EACH CHANNEL IF THE LOAD IMPEDANCE CHANGES FROM AN ESTABLISHED BASELINE. SEPARATE HIGH AND LOW SENSITIVITY CONTROLS ARE PROVIDED TO ELIMINATE FALSE TRIPPING. A MASTER FAULT INDICATOR ALSO LIGHTS TO ALERT THE USER TO THE PROBLEM. THE MASTER FAULT INDICATOR CORRESPONDS WITH A REAR PANEL DRY-PAIR SWITCH CLOSURE, ALLOWING ADDITIONAL INDICATORS OR ALARMS TO BE INSTALLED IN REMOTE LOCATIONS. A SEPARATE EMERGENCY PAGE ( E-PAGE) INPUT PROVIDES A SIMPLE MEANS OF SWITCHING BETWEEN NORMAL PROGRAM AND E-PAGE ON DEMAND. E-PAGE IS ACTIVATED BY PROVIDING 5-50 V (AC OR DC) TO THE E-PAGE CONTACT PAIR. EACH CHANNEL MAY BE INDIVIDUALLY SET TO ALLOW E-PAGE, IGNORE E-PAGE, OR MUTE WHEN E-PAGE IS ACTIVATED. THE EIGHT BALANCED PROGRAM INPUTS ARE ASSOCIATED WITH SEVEN “GANGING SWITCHES, ALLOWING EACH INPUT LINE TO BE SELECTIVELY PARALLELED TO ADJACENT INPUTS AND GREATLY SIMPLIFYING INSTALLATION WIRING. THE MA AMP MAY BE PLACED IN STANDBY FOR REDUCED POWER CONSUMPTION, ALLOWING IT TO BE BATTERY POWERED FOR EXTENDED PERIODS (UP TO SEVERAL DAYS). STANDBY CAN BE SET TO TRIGGER AUTOMATICALLY WHEN AC POWER FAILS AND THE BATTERY TAKES OVER. UPON AN E-PAGE COMMAND, THE UNIT “WAKES UP AND IS READY TO MAKE CRITICAL, LIFE SAVING ANNOUNCEMENTS WITHIN A FEW SECONDS. MASTER FUNCTIONS INCLUDE OVERALL CUE LEVEL, AN E-PAGE TEST SWITCH, A STANDBY TEST SWITCH, AND A MAINTENANCE SWITCH WHICH DISABLES THE REMOTE FAULT INDICATOR FOR TEST PURPOSES. WE EVEN PROVIDE A DRY-PAIR SWITCH CLOSURE SO YOU CAN REMOTELY MONITOR THE STATE OF THE MAINTENANCE SWITCH. BOTH SERIES A AND SERIES B MODELS INCLUDE SIGNAL INDICATORS WHICH SHOW THE PRESENCE OF INPUT SIGNALS ON EACH CHANNEL; CLIP/LIMIT INDICATORS TO SHOW THAT THE CLIP ELIMINATOR CIRCUITRY HAS BEEN ACTIVATED, AND A FAULT INDICATOR WHICH LIGHTS WHEN SERVICE IS INTERRUPTED FOR ANY REASON. THE REAR PANEL IS EQUIPPED WITH EUROBLOCK CONNECTORS FOR SIGNAL INPUT, SPEAKER OUTPUT, AND ALL CONTROL AND MONITORING I/O CONNECTIONS. SOUND LIKE A LOT? THERE'S MORE: THE MA SERIES A MODELS CAN BE MONITORED AND CONTROLLED BY A REMOTE COMPUTER, USING APOGEE'S INDUSTRY-LEADING AMPNET 98 SOFTWARE CONTROL SYSTEM. IT'S AS SIMPLE AS ADDING A SMALL DAUGHTER-BOARD TO EACH OF THE CHANNELS THAT YOU WISH TO MONITOR AND CONTROL, PLUS A SINGLE MASTER INTERFACE BOARD. CONTROL FUNCTIONS INCLUDE LEVEL CONTROL, CHANNEL CUE FUNCTION, ACTIVATION OF E-PAGE, AND MORE. MONITORING CAPABILITIES INCLUDE SIGNAL PRESENCE, CLIP/LIMIT, POWER(FOR EACH CHANNEL INDIVIDUALLY), LOAD IMPEDANCE HIGH/LOAD IMPEDANCE LOW, AND MASTER POWER/BATTERY BACKUP STATUS. IF YOUR SYSTEM NEEDS 70 VOLT OR 100 VOLT CONSTANT VOLTAGE OUTPUTS, THE MA AMPLIFIER CAN BE MATED WITH A COMPANION PRODUCT THAT PROVIDES TRANSFORMER ISOLATION AND VOLTAGE GAIN. WIRING IS SIMPLE, AS BOTH UNITS USE STANDARD EUROBLOCK STYLE CONNECTORS. A OPTIONAL SPARE CHANNEL SUBSTITUTION SWITCH WILL BECOME AVAILABLE IN 1998. THIS ADD-ON UNIT WILL BE PROGRAMMABLE TO AUTOMATICALLY ENGAGE UNDER FAULT CONDITIONS, OR THE INSERTION OF THE SPARE CHANNEL MAY BE MANUALLY CHOSEN BY LOCAL CONTROL OR FROM A REMOTE COMPUTER STATION EQUIPPED WITH AMPNET 98? THE PRICE FOR THIS COMPREHENSIVE SYSTEM WILL SURPRISE YOU. VERY PLEASANTLY! CONTACT APOGEE TODAY TO ARRANGE A DEMONSTRATION. POWER OUTPUT (INDIVIDUAL CHANNELS) 160 WATTS PER CHANNEL INTO 8 OHMS 250 WATTS PER CHANNEL INTO 4 OHMS 200 WATTS PER CHANNEL INTO 2 OHMS (SINE WAVE @ 1 KHZ, 0.3% THD) POWER OUTPUT (ALL CHANNELS DRIVEN) 200 WATTS PER CHANNEL INTO 4 OHMS (SINE WAVE @ 1 KHZ, 0.3% THD) 250 WATTS PER CHANNEL INTO 4 OHMS (PINK NOISE 20 HZ - 20 KHZ, 6 DB CREST FACTOR) FREQUENCY RESPONSE (SHAPED WITH LOW PASS & HIGH PASS FILTERS) -3 DB AT 23 HZ -3 DB AT 20 KHZ SMPTE INTERMODULATION DISTORTION <0.2%, 60 HZ & 7 KHZ, RATED POWER AT 4 OHMS INPUT COMMON MODE REJECTION GREATER THAN 90 DB BALANCED VOLTAGE GAIN 32 DB INPUT SENSITIVITY .775 VRMS INPUT IMPEDANCE 20K OHMS BALANCED, 10K OHMS UNBALANCED HUM & NOISE BETTER THAN -94 DBA, REF 200W @ 4 OHMS CROSSTALK BETTER THAN -70 @ 1 KHZ CONNECTORS SIGNAL INPUT: BALANCED LINE LEVEL USING DETACHABLE EUROBLOCK CONNECTORS SPEAKER OUTPUT: DETACHABLE EUROBLOCK CONNECTORS ACCEPT #12 AWG STRANDED WIRE REMOTE E-PAGE ACTIVATION: EUROBLOCK, 5-50 V (AC OR DC), 1 MA CURRENT DRAIN REMOTE FAULT INDICATOR: EUROBLOCK, RELAY OPENS MAKING CONTACT UPON FAULT CONDITION (NO AND NC CONTACTS AVAILABLE) REMOTE ALL MUTE: EUROBLOCK, 5-50 V (AC OR DC), 1 MA CURRENT DRAIN POWER INLET: IEC 320 INLET CUE BUS OUTPUT: EUROBLOCK, +4 BALANCED DBU LINE LEVEL E-PAGE INPUT: EUROBLOCK, +4 BALANCED DBU LINE LEVEL BATTERY BACKUP INLET: NEUTRIK SPEAKON TYPE. ACCEPTS APOGEE'S PROPRIETARY BATTERY SYSTEM. MAINTENANCE SWITCH STATE: EUROBLOCK, NC & NO CONTACTS PROVIDED CHANNEL FUNCTIONS (SERIES A ONLY) E-PAGE SELECT: EACH CHANNEL MAY BE SET BY INTERNAL JUMPERS TO ACCEPT E-PAGE, IGNORE E-PAGE, OR MUTE UPON ACTIVATION OF E-PAGE CUE SWITCH: ASSIGNS SPEAKER LEVEL TO THE CUE BUS. CUE BUS OUTPUT IS PADDED TO LINE LEVEL. ATTENUATION: SELECTABLE IN 0.5 DB LEVELS FROM 0 TO-127.5 DB BY AN 8-WAY DIP SWITCH. CONTINUOUSLY ADJUSTABLE TRIMPOT PROVIDES INFINITE VARIATION WITHIN RANGE SELECTED BY DIP SWITCH. MODEL B OFFERS CONTINUOUSLY ADJUSTABLE TRIMPOT ONLY. POWER ON/OFF LOAD SENSE ON LOAD SENSE ADJUST (NULL) CONTROL LOAD SENSE HIGH IMPEDANCE SENSITIVITY LOAD SENSE LOW IMPEDANCE SENSITIVITY ENABLE/DISABLE BATTERY BACKUP: (INTERNAL JUMPER) CHANNEL INDICATORS (MODEL A) POWER, E-PAGE, CUE, LOAD LOW, LOAD HIGH, CLIP/LIMIT, SIGNAL PRESENCE, FAULT CHANNEL INDICATORS (MODEL B) POWER, CLIP/LIMIT, SIGNAL PRESENCE, FAULT MASTER FUNCTIONS (MODEL A ONLY) MAINTENANCE: DISABLES REMOTE FAULT INDICATOR(S) TO AVOID FALSE ALARMS STANDBY TEST: PUTS THE UNIT IN STANDBY MODE FOR TEST AND VERIFICATION E-PAGE TEST: ACTIVATES E-PAGE INPUT. NOTE: THE EFFECT OF ACTIVATING THE E-PAGE INPUT IS SUBJECT TO THE JUMPER SETTINGS ON EACH CARD. SEE E-PAGE SELECT UNDER CHANNEL FUNCTIONS. CUE LEVEL: PROVIDES A MASTER CUE OUTPUT LEVEL MASTER INDICATORS (MODEL A ONLY) MAINTENANCE INDICATOR: INDICATES THAT MAINTENANCE SWITCH HAS BEEN DEPRESSED (DISABLING REMOTE FAULT INDICATOR(S) STANDBY: INDICATES UNIT IS IN STANDBY MODE (LOW POWER DRAIN), FROM EITHER ABSENCE OF AC POWER OR ACTIVATION OF THE STANDBY TEST SWITCH FAULT: INDICATES PRESENCE OF A FAULT CONDITION ON ANY CHANNEL OR PRESENCE OF A DEVIATION OF LOAD IMPEDANCE FROM THE ESTABLISHED BASELINE E-PAGE: INDICATES THAT E-PAGE HAS BEEN SELECTED BY EITHER THE E-PAGE TEST SWITCH OR BY CLOSURE OF REMOTE E-PAGE SWITCH CONTACTS PROTECTION (BOTH MODELS) INDIVIDUAL CHANNEL FUSE, MASTER POWER SUPPLY CIRCUIT BREAKER/ON-OFF SWITCH, HIGH TEMPERATURE PROTECT, DC PROTECT, OVERCURRENT PROTECT, TURN-ON DELAY WITH SIGNAL RAMP-UP, ULTRASONIC AND SHORT CIRCUIT PROTECT COOLING FRONT TO REAR, TWO-SPEED DC FAN CONSTRUCTION 16 GAUGE STEEL CHASSIS, 10 GAUGE FRONT-TO-REAR RACK RAILS DIMENSIONS 19" (483 MM) WIDE, 7 (178 MM, 4 EIU RACK SPACES) HIGH, 18" (457 MM) DEEP WEIGHT 63.5 LBS. FULLY LOADED (28.8 KG)

Condition report

Listed before A/B/C grading.

The seller described its condition as: LIKE NEW IN ORIGINAL PACKAGING (10)

Available now in Amplifiers & DSP

All amplifiers & dsp